Home > News & Updates > Electronics News Updates > TEKTRONIX ADDS INDUSTRY-FIRST TECHNOLOGY WHICH ELIMINATES PULSE TUNING IN NEW ALL-IN-ONE 2601B-PULSE SYSTEM SOURCEMETER

TEKTRONIX ADDS INDUSTRY-FIRST TECHNOLOGY WHICH ELIMINATES PULSE TUNING IN NEW ALL-IN-ONE 2601B-PULSE SYSTEM SOURCEMETER

Summary of TEKTRONIX ADDS INDUSTRY-FIRST TECHNOLOGY WHICH ELIMINATES PULSE TUNING IN NEW ALL-IN-ONE 2601B-PULSE SYSTEM SOURCEMETER


Tektronix announced the 2601B-PULSE System SourceMeter, combining a high-speed PulseMeter pulser with DC SMU functions. It sources 10 μs pulses up to 10 A and 10 V without manual pulse tuning for device impedances up to 3 μH, reducing self-heating errors. It retains all 2601B SMU ranges (40 V, 3 A DC, 10 A pulse), includes dual 1 MS/s 18-bit digitizers for simultaneous current and voltage waveforms, and is supported by KickStart v2.3. It targets VCSEL/LIDAR, LED, semiconductor characterization, fault power, and surge protection testing.

Parts used in the2601B-PULSE System SourceMeter:

  • 2601B-PULSE System SourceMeter instrument
  • PulseMeter technology (built into 2601B-PULSE)
  • Standard Model 2601B SMU ranges (40 V, 3 A DC, 10 A Pulse)
  • Dual 1 MS/sec 18-bit digitizers (built into 2601B-PULSE)
  • Keithley/Tektronix KickStart Instrument Control Software version 2.3
  • VCSELs and LEDs (as test devices; application context)

Tektronix, Inc. today announced the new 2601B-PULSE System SourceMeter® 10μs Pulser/SMU Instrument, integrating a high-speed current pulser with DC source and measurement functions in one instrument. The new system incorporates PulseMeter™ technology for sourcing current pulses as short as 10μsec at 10A and 10V without the need to manually tune the output to match device impedance up to 3μH. This is critical for minimizing device self-heating, which for optical devices, can result in erroneous measurements and the potential for damaging test equipment. The new 2601B-PULSE also includes all current and voltage source measure unit (SMU) ranges that are available in Keithley’s standard Model 2601B System SourceMeter® (40V, 3A DC, 10A Pulse). In addition, Tektronix is also releasing version 2.3 of Keithley’s Instrument Control Software “KickStart” to support the pulsing function of the 2601B-PULSE.

The 2601B-PULSE System SourceMeter® affirms Tektronix’s commitment to the advancement of technology through leading test and measurement solutions,” says Chris Bohn, vice president and general manager at Keithley/Tektronix. “This new instrument will bring better testing capabilities for engineers, including those who rely on industry-first technology to take innovative strides in automotive applications, connected vehicles and autonomous driving.

Advancement in Testing with LIDAR in Mind

The 2601B-PULSE System SourceMeter® was developed to serve the needs and complications of testing vertical-cavity surface-emitting lasers (VCSELs), which are mission-critical for automotive light detection and ranging (LIDAR) applications. The instrument is ideal for testing VCSELs and LEDs, semiconductor device characterization, fault power management testing, surge protection testing and beyond. Built-in dual 1 MS/sec,18-bit digitizers enhance the pulser’s measurement function, enabling users to acquire both pulse current and voltage waveforms simultaneously, without the need to use a separate instrument.

Read more: TEKTRONIX ADDS INDUSTRY-FIRST TECHNOLOGY WHICH ELIMINATES PULSE TUNING IN NEW ALL-IN-ONE 2601B-PULSE SYSTEM SOURCEMETER

Quick Solutions to Questions related to2601B-PULSE System SourceMeter:

  • What is the shortest pulse width the 2601B-PULSE can source?
    The 2601B-PULSE can source current pulses as short as 10 μs.
  • How much current and voltage can the pulser deliver?
    The pulser can deliver up to 10 A and 10 V pulses.
  • Does the 2601B-PULSE require manual tuning for device impedance?
    No, PulseMeter technology eliminates the need to manually tune the output for device impedances up to 3 μH.
  • What DC and pulse SMU ranges are included?
    It includes the same SMU ranges as the standard Model 2601B: 40 V, 3 A DC, and 10 A Pulse.
  • Can the instrument measure pulse current and voltage waveforms simultaneously?
    Yes, built-in dual 1 MS/sec, 18-bit digitizers enable simultaneous acquisition of pulse current and voltage waveforms.
  • What software supports the pulsing function of the 2601B-PULSE?
    Keithley’s Instrument Control Software KickStart version 2.3 supports the pulsing function.
  • What applications is the 2601B-PULSE designed for?
    It is ideal for testing VCSELs and LEDs, semiconductor device characterization, fault power management testing, and surge protection testing, with LIDAR/automotive applications in mind.
  • Why is eliminating pulse tuning important?
    Eliminating pulse tuning minimizes device self-heating that can cause erroneous measurements and risk damaging test equipment.

About The Author

Ibrar Ayyub

I am an experienced technical writer holding a Master's degree in computer science from BZU Multan, Pakistan University. With a background spanning various industries, particularly in home automation and engineering, I have honed my skills in crafting clear and concise content. Proficient in leveraging infographics and diagrams, I strive to simplify complex concepts for readers. My strength lies in thorough research and presenting information in a structured and logical format.